Integrated system design, pre-installation and pre-commissioning, reducing the number of on-site adjustments.
AI intelligent temperature control, system temperature difference ≤ 4°C, reduce 30% auxiliary power consumption.
Multi-stage PCS high-efficiency energy conversion technology to enhance the system charging and discharging efficiency up to 90%.
Cloud AI optimization algorithms provide decision-making basis through high-accuracy forecasting for complex system operation and electricity market transactions, which can increase annual revenue by 15% to 20% and shorten thereturn on investmentcycle.
User-friendly terminal design adaptable to various wire gauge requirements.
Significantly reduced operational noise levels as low as 70dB.
Intelligent online monitoring, rapid state detection and fault recording to achieve rapid system fault location and analysis.
Supports remote operation and maintenance, with intelligent O&M enhancing the efficiency of energy storage station operations, asset returns, and service revenues.


|
Nominal Capacity |
261kWh |
|
Nominal Power |
125kW |
|
Battery Voltage Range |
676–949VDC |
| Cell Type | LFP3.2V / 314Ah |
| System Configuration | 1P260S |
| Nominal Power |
125kW
|
|
THDi
|
< 3% |
|
THDu (off-grid)
|
< 3%
|
| DC Component | < 0.5% |
| Nominal Voltage |
400 V AC
|
| AC Voltage Range |
340–460 V AC
|
|
Frequency Range
|
50 ± 5 Hz
|
| Operating Ambient Temperature Range |
–30°C to +55°C (> 45°C derating) (-22°F to 131°F, >113°F derating) |
|
Storage ambient temperature range
|
–30°C to +55°C (-22°F to 131°F) |
| Relative Humidity |
5%–95% RH (non-condensing)
|
| Max. Operating Altitude | 2000 m (6562 ft) |
| Ingress Protection (IP) Rating | IP55 |
|
System efficiency
|
≥ 87%@0.5P
|
|
Auxiliary power
|
Self-powered
|
|
Cooling method
|
Liquid cooling
|
|
Cycle life
|
≥ 7000 cycles
|
| Weight | 2700 ± 50 kg (5952 ± 110 lb) |
| Corrosion-proof Grade |
• IEC Version: C3, C4 (optional) • UL Version: C4
|
| Dimensions (W × H × D) |
• IEC Version: 1150 × 2400× 1500mm (45.3 × 94.5 × 59.1 in, without lifting eyes) • UL Version: 1520 × 2000 × 1390 mm (59.8 × 78.7 × 54.7 in, without lifting eyes)
|
| Fire Suppression System |
• IEC Version: Smoke detector, heat detector, aerosol, horn strobe • UL Version: Smoke detector, heat detector, aerosol, horn strobe, gas detector(H), exhaust device, inlet device |
| Communication Interface |
Ethernet, CAN, RS485, 4G
|
| Standard Compliance |
• IEC Version: IEC62619, IEC63056, IEC62040, IEC62477, UN38.3 • UL Version: NFPA 855, NFPA 69, NFPA 70, NFPA 72, UL 9540A, UL 9540, UN38.3, UL 1741 |
|
|
|
|
|
©2026 Shenzhen CLOU Electronics Co., Ltd.