Renewable power plant integration (ramp rate control, energy shifting)
Grid ancillary control (frequency regulation, peak shaving)
Distributed network and micro-grid (peak shaving, autonomous operation)
High power density, excellent heat dissipation,ensuring stable operation of equipment
Comprehensive detections and protections,ensuring the reliable operation of equipment
Compatible with a variety of communication protocols
Equipped with PQ, VF, SVG, VSG and other functions
Supporting low/high voltage ride through (L/HVRT)
Integrated monitoring function and fast troubleshooting
Modular design, easy to maintain


|
DC Voltage Range |
1000 V-1500 V |
|
Max. DC Voltage |
1500 V |
|
Max. DC Current |
1825 A |
|
Rated Power |
1725 kW @ 45°C |
|
Max. AC Output Power |
1898 kW @ 30°C |
|
Rated AC Voltage |
690 V AC, 3W + PE |
|
AC Voltage Range |
587–759 V |
|
Rated Grid Frequency |
50 Hz/60 Hz |
|
Grid Frequency Range |
45–55 Hz/55–65 Hz |
|
Max. AC Current |
1588 A @ 30℃ |
|
AC Current THD (THDi) |
< 3% (at rated power) |
|
Power Factor |
> 0.99 (at rated power) |
|
Rated AC Voltage |
690 V, 3W + PE |
|
AC Voltage Range |
587–759 V |
|
AC Voltage THD (THDu) |
< 3% (linear load) |
|
DC Voltage Component |
< 0.5% Un (linear balance load) |
|
Unbalanced Load Capacity |
100% unbalanced load |
|
Rated Grid Frequency |
50 Hz/60 Hz |
|
Max. Efficiency/CEC Efficiency |
99% |
|
DC Breaker |
Supported |
|
DC Fuse |
Supported |
|
AC Breaker |
Supported |
|
AC Overcurrent Protection |
Supported |
|
Insulation Impedance Detection |
Supported |
|
Dimensions (W × D × H) |
800 mm × 2570 mm × 1700 mm |
|
Weight (approx.) |
≤ 1200 kg |
|
Operating Ambient Temperature Range |
–35°C to +60°C (> 45°C derating) |
|
Relative Humidity Range |
0–100% (non-condensing) |
|
Max. Operating Altitude |
5000 m (> 3000 m derating) |
|
Ingress Protection (IP) Rating |
IP65 (electronic cavity), IP55 (main air duct) |
|
Anti-corrosion Degree |
C4 , C5 (optional) |
|
Cooling Method |
Forced air cooling |
|
Isolation Mode |
Non-isolated type (transformer external) |
| Communication Interface |
RS485, CAN, Ethernet, Fiber (optional) |
|
Communication Protocol |
Modbus TCP, IEC 104, IEC 61850 |
|
Standard Compliance |
EN 50549, IEC 62477, IEC 61000 |
|
|
|
|
|
©2026 Shenzhen CLOU Electronics Co., Ltd. All rights reserved. Subject to change without notice. Version 1.0 07/2026 |