Tel: +1 518-289-5355
Email: info.us@szclou.com
Addr: 2860 Guilder Dr. Plano, TX 75074, US

10-foot design, weighing less than 23 tons, enabling easy transportation and deployment in confined spaces.
Integrated AC/DC bi-directional inverter, reducing commissioning time.
Multi-level electrical protection, fire protection, arcflash analysis, and collaborative protection.
Intelligent management of battery health for earlywarning of faulty batteries.
Compliant with IEEE 693 high seismic level.
Modular design reduces failure impacts andimproves system uptime.
Active balancing technology and bio-inspiredsolutions enhance battery lifespan and systemdischarge capacity.
Active balancing technology reduces O&M costs forenergy storage stations.
Rapid state detection and fault recording achieverapid positioning and analysis of system faults.


| Cell Type | LFP3.2 V / 314 A |
| Battery Configuration |
5P416S (Aqua-C2.5S-2089-500-4h) 6P416S (Aqua-C2.5S-2508-625-4h) |
| Nominal Energy |
2089 kWh (Aqua-C2.5S-2089-500-4h)
|
| Battery Voltage Range | 1081.6~1497.6V |
| Nominal Battery Voltage | 1331.2 V |
| Nominal Power |
500kVA (Aqua-C2.5S-2089-500-4h) 625kVA (Aqua-C2.5S-2508-625-4h) |
| Current THD | < 3% (nominal power) |
| DC Component | < 0.5% |
| Nominal Voltage |
550 V |
| AC Voltage Range | 495 V - 605 V(<498 V derating) |
| Nominal Frequency | 50 Hz / 60 Hz |
|
Maximum Current
|
580 A × 3 phases (Aqua-C2.5S-2089-500-4h)
630 A × 3 phases (Aqua-C2.5S-2508-625-4h)
|
| Power Factor | ≥0.99 (nominal power) |
| Power Factor Range | - 1 to +1 |
| Operating Ambient Temperature Range | -30 °C to +50 °C |
| Relative Humidity | ≤ 100% RH (non-condensing) |
| Max. Operating Altitude | 3000 m |
| Ingress Protection (IP) Rating |
IP66 |
|
Cooling method
Method
|
Intelligent liquid cooling |
| Noise | ≤75dB (@ 1 m, ambient temperature 35℃) |
| Weight (approx.) |
≤ 23000 kg (Aqua-C2.5S-2089-500-4h) ≤ 25000 kg (Aqua-C2.5S-2508-625-4h) |
| Corrosion-proof Grade |
C4, C5 (optional) |
| Seismic Level |
IEEE 693 high design level qualification
|
| Dimensions (W × D × H) |
3126 × 2896 × 2438 mm
|
| Fire Suppression System | Fire control alarm panel, smoke and heat detectors, alarm bell, horn strobe, gas detector, ventilation system (compliance with NFPA 69), dry pipes with sprinklers, aerosol |
| Communication Interface | Ethernet |
|
Communication Protocol
|
Modbus-TCP, IEC 104, IEC 61850
|
| Standard Compliance |
IEC 62933-5-2, IEC 61000, IEC 62619, IEC 63056, IEC 62477-1, JETGR0004-1-2.1, JETGR0005-1-1.0, JEAC9701-2024, JC-STAR |
|
|
|
|
|
©2026 Shenzhen CLOU Electronics Co., Ltd.
All rights reserved. Subject to change without notice. Version 1.0 02/2026
|